What Wire Size for a 20A Branch Circuit?
A 20 amp branch circuit — kitchen small appliances, bathroom outlets, garage tools — takes 12 AWG copper on a 20A breaker, full stop. Twelve-gauge THHN is rated 25A at 75C, but the breaker caps the circuit at 20A, and continuous loads (3+ hours) are limited to 80%, or 16A. This guide works the sizing, the derating exceptions, and the inspection points.
💡 At a Glance
A 20A branch circuit takes 12 AWG copper on a 20A breaker — continuous loads capped at 16A.
ƒx Key Formula
Wire ampacity ≥ breaker rating; continuous load ≤ 80% of breaker; VD ≤ 3% on branch
Step-by-Step Takeoff
-
1
List the load: five 1800W general outlets at 120V draw 15A each worst-case, but a 20A circuit serves them together under diversity.
-
2
Pick the breaker first: 20A for general receptacles; size the wire to match or exceed it — 12 AWG copper (25A at 75C).
-
3
Apply the 80% rule for continuous loads: a heater or grow light running 3+ hours may not exceed 16A on this circuit.
-
4
Check ambient and bundling: above 30C or more than 3 current-carrying conductors in one conduit, derate — often forcing 10 AWG.
-
5
Verify terminal ratings: most receptacles are 60/75C — size to the lowest-rated termination in the chain.
-
6
Add AFCI protection where required (bedrooms, living areas) and GFCI in wet locations.
-
7
Price the run (wire per foot plus breaker) in the Electrical Calculator and export the materials list.
⚠️ Common Mistakes
-
1
Putting 14 AWG on a 20A breaker — the breaker must protect the smallest wire on the circuit.
-
2
Ignoring the 80% continuous rule — heaters and grow lights running 3+ hours max out at 16A.
-
3
Skipping derating — more than 3 current-carrying conductors in one conduit forces a size up.
Guide FAQ
Can I use 14 AWG on a 20A breaker?
No — 14 AWG is limited to 15A circuits. The breaker must protect the smallest wire on the circuit.
When do I need 10 AWG instead of 12?
Long runs with voltage drop over 3%, hot attics above 40C, or 4+ conductors bundled in one conduit.
How many outlets on a 20A circuit?
Residential code allows generous counts under diversity, but plan ~8–10 general receptacles so vacuum cleaners plus heaters do not trip it.
What does the 80% rule mean exactly?
Continuous loads (3+ hours) may use only 80% of breaker rating: 16A on a 20A circuit, 12A on a 15A.
Aluminum instead of copper?
Possible with CO/ALR devices and anti-oxidant, but upsize one gauge and expect inspector questions.
Related Guides
Voltage Drop on a 100 ft Run: How to Fix It
The 2KIL/CM formula worked for 100 ft at 120V, upsizing rules, and the 60 ft threshold.
How Many Wires Fit in 3/4" PVC Conduit?
The 40% fill rule worked: THHN areas by gauge, derating limits, and conduit upsizing calls.
Is My 200A Panel Overloaded? Do the Math
Existing 80A load plus new circuits against a 200A service, demand factors, and upgrade triggers.