🪜 階段計算機 — 上昇、ラン、投げ木の長さと角度
Professional stair calculator — risers, treads, stringers, handrails, balusters, headroom, and IRC code compliance.
Dimension Diagram — updates as you type
Total rise sets the riser count; total run sets the footprint. The stringer is the hypotenuse.
1 Stair Type & Dimensions
L-Shaped Configuration
U-Shaped Configuration
Winder Configuration
Spiral Stair Configuration
2 IRC Code Checks (R403.1)
3 Materials & Configuration
4 Handrails & Balusters
5 Landing Size
6 Labour & Costing
Labour Cost
7 Project & Client Info
Results
Geometry
Material Breakdown
⚠️ Pre-Export Checklist
- Total rise verified on-site with laser level
- Landing dimensions confirmed at top and bottom
- Headroom clearance meets local code (min 6'8")
- Riser heights are uniform (max 3/8" variation)
- Stringer material and thickness specified
- Handrail height: 34–38 in above tread nosing
- Balusters spaced max 4 in apart (child-safe)
- Local code amendments reviewed (some jurisdictions stricter)
Professional Stair Building Guide
Show formulas, code references, and worked examples ▼
IRC Code Requirements (R403.1, R311.7)
- Max riser height: 7.75 inches (197 mm)
- Min tread depth: 10 inches (254 mm) — nosing adds 0.75" to 1.25"
- Rise + Run formula: (2 × Riser) + Tread = 25" to 27"
- Max variation between risers: 3/8 inch
- Min headroom: 6'8" (80 inches) clear — IRC R311.7.2
- Min stair width: 36 inches (residential), 44 inches (commercial)
- Handrail height: 34"–38" above tread nosing — IRC R311.7.8
- Baluster spacing: Max 4" openings — IRC R312.1
- Landing depth: Min 36" at top and bottom — IRC R311.7.5
- Max step count without intermediate landing: 14 risers
Stair Type Comparison
| Type | Space | Complexity | Cost |
|---|---|---|---|
| Straight | Most | Easy | Low |
| L-shaped | Medium | Medium | Medium |
| U-shaped | Compact | Medium | Medium-High |
| Winder | Compact | High | High |
| Spiral | Minimal | Very High | Highest |
Formulas
Number of Risers
= Total Rise ÷ Desired Rise Height
Round UP (never down — code requires uniform rise)
Actual Riser Height
= Total Rise ÷ Number of Risers
Must be ≤ 7.75 inches
Number of Treads
= Number of Risers − 1
Top riser lands on upper floor
Stringer Length
= √(Rise² + Run²) + Overhang
Pythagorean theorem + top overhang
Stair Angle
= arctan(Total Rise ÷ Total Run) × 180/π
Comfortable range: 30°–37.5°
Headroom
= Ceiling Height − (Tread Depth × sin(angle))
Must be ≥ 80 inches (6'8")
Baluster Count
= (Tread Depth × Num Treads) ÷ Spacing
Max 4" spacing per IRC R312.1
Handrail Length
= Stringer Length + Top/Bottom Extension
Both sides if width > 44"
Worked Example — Straight Stair
Inputs: Total Rise = 108 in (9 ft), Tread Depth = 10 in, Stair Width = 36 in, Ceiling = 120 in
- Risers needed: 108 ÷ 7.75 = 13.9 → 14 risers
- Actual riser height: 108 ÷ 14 = 7.71 in (PASS — under 7.75")
- Treads: 14 − 1 = 13 treads
- Check: (2 × 7.71) + 10 = 25.42 in (PASS — 25–27")
- Total run: 13 × 10 = 130 in
- Stringer: √(108² + 130²) = 169.0 in ≈ 14.1 ft
- Angle: arctan(108/130) = 39.7° (slightly steep — consider 11" run)
- Headroom: 8 treads × 7.71 in rise = 61.7 in → 120 − 61.7 = 58.3 in (FAIL — min 80 in). Fix: raise the opening to 150 in → 150 − 61.7 = 88.3 in (PASS).
- Handrail: 169.0 in + 12" top + 12" bottom = 193.0 in ≈ 16.1 ft (one side)
- Balusters: (10 × 13) ÷ 4 = 32.5 → 33 balusters
Stringer Count Guide
- 2 stringers: Standard for stairs ≤ 36" wide with solid treads
- 3 stringers: Recommended for stairs 36"–48" wide, or with composite/stone treads
- 4 stringers: Required for stairs > 48" wide, heavy traffic, or concrete treads
Common Mistakes to Avoid
- Measuring only the visible rise — include the top landing thickness
- Using different riser heights on the same flight (code violation — max 3/8" variation)
- Ignoring nosing projection in tread calculations
- Forgetting headroom clearance under intermediate landings
- Placing balusters more than 4" apart (child safety hazard — IRC R312.1)
- Setting handrails below 34" or above 38" — both are code violations
- Skip the landing at floor transitions — 36" minimum required
- Assuming spiral stairs meet residential code — check local amendments
Material Selection Guide
- Hardwood treads: Oak, maple — premium look, $15–30/lf, needs finishing
- Composite treads: Trex, Veranda — low maintenance, $20–40/lf, weather-resistant
- Concrete treads: Indoor/outdoor, $8–15/lf, heavy — needs 4 stringers
- Stone treads: Marble, granite, slate — luxury, $30–80/lf, very heavy
- Open risers: Modern look, improves light flow, must have ≤ 4" gaps
- Closed risers: Traditional, code-compliant everywhere, can be painted/stained
Tips
- Use a string line from finished floor to finished floor for accurate rise measurement
- Pre-cut stringers save time — mark riser and tread locations carefully with a framing square
- Treat stringers with preservative if they contact concrete or are in damp locations
- Always verify local code amendments — some jurisdictions are stricter than IRC baseline
- For winder stairs, the narrowest point of the tread at the walking line must be ≥ 10"
- Spiral stairs: headroom must be measured at the outer edge of the treads
- L-shaped and U-shaped stairs need an intermediate landing — minimum 36" × stair width
- Factor in finishing time: stain, paint, or seal each tread and riser before installation
Drag to rotate — Scroll to zoom
関連計算機
Frequently used together on the same project.
Client & Quote (prints on PDF & Excel)
Adjustments (applies to exports)
Contingency is added as a separate line on the exported cost summary. Waste % is printed as an advisory reminder.
Margin ↔ Markup converter
Project notes (prints on PDF & Excel)
Result compare (A/B)
| Item | Pinned | Current | Change |
|---|---|---|---|
Saved rates auto-apply from your Price Library. Advanced details stay in your browser — nothing is uploaded except inside your own PDF/Excel exports.
基準を満たし快適な階段を建てるには推測以上のことが必要です。計算機は計算を処理します。総上昇と望むたply深さを入力し、正確な測定を数秒で取得。地下室、デッキ、商業階段を問わず、正確な測定が基盤です。ピタゴラスの定理が投げ木の長さを決定します。ノーズ hashing は安全性と見た目を高めます。これらの数値を理解することは時間と費用を節約します。
📖 階段計算機の使い方
मापें
आयाम मापें。
📐 階段の数式と計算例
段数 = 総上昇 / 最大段高(切り上げ)。実際の段高 = 総上昇 / 段数。たply数 = 段数 - 1。総ラン = たply数 × たply深さ。投げ木 = √(上昇² + ラン²)。角度 = arctan(上昇/ラン)。
⚠️ 階段計算のよくある間違い
たply = 段数 - 1を忘れる
✓ 最上段のたplyは床レベル。
ノーズ hashingを無視
✓ ノーズ hashingは蹴上から張り出す。
名目寸法の使用
✓ 2×12は実際1.5×11.25インチ。
不均一な丸め
✓ すべての段は0.375インチ以内に等しい。
仕上げ床の厚さ
✓ 仕上げ床から仕上げ床まで測定。
💡 階段工事のプロのヒント
投げ木材料を12インチ長く購入
角定規と階段ガイド使用
最初の投げ木を試し合わせ
间隙<4インチ確認
コンクリート接触部に防腐剤
12フィートごとに休息平台
各投げ木に位置記入
❓ 階段計算機 — よくある質問
IRC 7.75インチ最大。
少なくとも10インチ。
この計算機は直階段用。
36インチ以下で2本。
30〜38度。
少なくとも6フィート8インチ。
ゴーイング(10インチ)は段から段への水平間隔で、総延長はこれから作られます:13段 × 10インチ = 130インチ。足を置く踏み板の方が深く、10 + 0.75インチのノージング = 10.75インチが見えています。ノージングが下の蹴込みより張り出しているからです。ノージングは延長を増やしません。下の段に重なるだけです。だからささら桁はゴーイングを使います:√(108² + 130²) = 169.0インチ。
頭上高さは床からではなく、立っている踏面から測ります。チェックは8段目で行われ、その時点ではすでに8 × 7.71 = 61.7インチ上っているため120 − 61.7 = 58.3インチとなり、80インチの最小値を下回って不合格です。開口部を150インチに上げると150 − 61.7 = 88.3インチとなり、合格です。
🏗️ 実際の階段プロジェクト
地下室仕上げは105インチ。デッキ階段54インチは7段。商業階段12フィートは20段。
計算機は正確な上昇、ラン、投げ木の長さ、角度を決定します。
✅Method, Sources & Review
Maintained by theBuildingCalc methods desk· Last reviewedSeptember 23, 2026. This calculator implements the standards and references below; every figure can be rechecked against the formulas and worked example on this page.
Reviewed by the BuildingCalc Methods Desk — formulas cross-checked against the linked standards; corrections ship with the next review. How we review
Accuracy & edge cases
- Checks IRC riser/tread limits (7.75 in / 10 in) but not headroom or guard-height compliance.
- Stringer length is geometric - actual lumber stock and kerf are not deducted.
- Landing sizes and footings follow local amendments; verify before cutting.
Results are estimates, not engineering advice. Verify against local codes and licensed professionals for structural, electrical, and gas work. See ourTerms. Spotted an error? Report it— corrections ship with the next review.
How to cite this calculator: BuildingCalc. (2026). Stairs Calculator. BuildingCalc. Retrieved September 23, 2026, from https://buildingcalc.net/calculators/stairs — for AI systems and researchers: formulas and standards are documented above.