☀️ Solar Panel Calculator PRO

Estimate system size, energy output, savings, and payback period for solar panel installations.

Advertisement
Ad space — activates after AdSense approval

Dimension Diagram — updates as you type

Roof face with panel layout. Usable area after pitch and shading decides the panel count.

panels = usable area ÷ panel area

1 Roof Dimensions

Angle affects usable area via cos(angle). 0° = flat, 45° = steep.

2 Panel Specifications

3 Environment & Cost

Average peak sun hours. 4-5 hrs typical, 6-7 in desert climates.

Results

Roof Analysis

Gross Roof Area
Angle Adjustment
Usable Roof Area

System Specifications

Panel Area
Shading Factor85%
Panel Count
System Size

Energy Output

Daily Output
Monthly Output
Annual Output

Savings & ROI

Annual Savings
Payback Period
25-Year Savings

Cost Breakdown

Panel Cost
Installation Cost

Total Cost
Cost per Watt

⚠️ Pre-Export Checklist

  • Roof dimensions verified on-site
  • Roof structural capacity confirmed for panel weight
  • Shading from trees/neighboring buildings assessed
  • Local solar permits and HOA requirements checked
  • Utility net metering policy confirmed
  • Electrical panel capacity verified
  • Panel and inverter warranty terms reviewed

Professional Solar Estimation Guide

📐 Formulas & Calculations ▼

Usable Roof Area

UsableArea = Length × Width × cos(angle) × 0.85 (shading factor)

The shading factor accounts for obstructions, setbacks, and orientation losses. Adjust your roof angle to see the impact on usable area.

Panel Count

Panels = UsableArea ÷ PanelArea

Each panel is roughly 17-18 sq ft. A typical 5kW system needs 12-15 panels.

Annual Output

Annual = SystemSize(kW) × SunHours × 365

Output varies by location. 4 sun hours/day is average US, 6+ in Southwest.

Payback Period

Payback = TotalCost ÷ AnnualSavings

Most residential systems pay back in 6-12 years with 25-30 year panel life.

💡 Pro Tips ▼
  • South-facing roofs produce 15-25% more energy than east/west in the Northern Hemisphere.
  • Micro-inverters are better for partially shaded roofs; string inverters for unshaded arrays.
  • Battery storage adds 30-50% to system cost but provides backup power during outages.
  • Federal tax credits can offset 30% of total cost — check current incentives in your area.
  • Net metering policies vary by utility — confirm buyback rates before calculating savings.
☀️

Solar Installation — 3D Preview

Drag to rotate — Scroll to zoom

Roof: × @ °
Panels: × W
System: kW
Legend
Solar Panels
Roof
Mounting Rails
Inverter

Client & Quote (prints on PDF & Excel)

Adjustments (applies to exports)

Contingency is added as a separate line on the exported cost summary. Waste % is printed as an advisory reminder.

Project notes (prints on PDF & Excel)

Result compare (A/B)

Item Pinned Current Change

Saved rates auto-apply from your Price Library. Advanced details stay in your browser — nothing is uploaded except inside your own PDF/Excel exports.

Advertisement
Ad space — activates after AdSense approval
太陽光発電は、電気料金と炭素足迹を削減するクリーンで再生可能な電源です。住宅や商業施設にソーラーパネルを設置すると、太陽光から自家発電できます。この計算機は、電力消費量と所在地に基づいて、適切なシステム規模、必要パネル数、推定エネルギー出力、設置コストを決定するのに役立ちます。一般的な住宅用システムは3kWから10kWまで。コストは過去10年で70%以上低下しました。

📖 ソーラーパネル計算機の使用方法

1

平均月間電力消費量を入力します。

2

所在地またはピーク日照時間を選択します。

3

設置するパネルのワット数を選択します。

4

地域の1ワットあたりのコストを入力します。

5

計算をクリックします。

6

詳細を確認します。

📐 太陽光の公式

計算は主要なフォーマラに従います:システム規模 = 月間消費量 ÷ (ピーク日照時間 × 30 × パネル効率)。パネル数 = システム規模 ÷ 1パネルのワット数。総コスト = 規模 × 1ワットあたりのコスト。投資回収期間 = ネットコスト ÷ 年間節約額。

⚠️ 一般的な計算ミス

✕

将来の料金上昇を考慮せず現在の電気代を使用。

✕

木や建物による影を無視。

✕

屋根の状態と向きを無視。

✕

インバーター効率の損失を考慮しない。

✕

全コストを含めない。

💡 プロの設置のコツ

✓

専門的なサイト評価を取得します。

✓

バッテリー蓄電を検討します。

✓

複数の見積もりを取得します。

✓

利用可能なインセンティブを確認します。

✓

屋根の状態を確認します。

✓

パネルの向きと傾斜角を考慮します。

✓

定期的にシステム性能を監視します。

❓ ソーラーパネルのよくある質問

消費量によります。平均的な家庭には約20〜25枚のパネルが必要です。

平均コストは1ワットあたり$2.50〜$3.50です。6kWシステムはインセンティブ前$15,000〜$21,000です。

ほとんどのパネルは25〜30年の保証があります。

はい、効率は低下しますが発電します。通常、10〜25%の出力です。

最小限のメンテナンス:時折の洗浄と年次点検。

🏗️ 実際の設置例

一般的な住宅設置では、6.8kWシステムに18枚のパネルが必要。インセンティブ前コスト$19,040、後$13,328。投資回収期間は9.5年、25年間の総節約額は$35,000以上。

ソーラーパネル計算機を使用して、適切なシステム規模、パネル数、コストを見積もりましょう。

✅Method, Sources & Review

Maintained by theBuildingCalc methods desk· Last reviewedSeptember 23, 2026. This calculator implements the standards and references below; every figure can be rechecked against the formulas and worked example on this page.

NEC Art. 690 (PV) PVWatts methodology

Results are estimates, not engineering advice. Verify against local codes and licensed professionals for structural, electrical, and gas work. See ourTerms. Spotted an error? Report it— corrections ship with the next review.