🔧免费 给排水 计算器 — 即时获取估算
WSFU per IPC · Drain & vent sizing · Water heater · Material breakdown
Pipe Schematic — updates as you type
Supply and drain runs. Fixture units size the pipes; length and fittings drive material cost.
1 Rooms & Fixtures
2WSFU Summary (IPC Table E103.3)
| Fixture | Cold WSFU | Hot WSFU | Total Qty | DFU |
|---|---|---|---|---|
| Totals |
3 Supply Pipe Sizing
4 Drain & Vent Sizing
5 Water Heater Sizing
6 Pipe Lengths & Insulation
7 Material Breakdown
| Category | Item | Qty / Length | Unit Price | Subtotal |
|---|---|---|---|---|
8 Pricing & Labour
Labour
Results
Supply System
Drain System
Fixtures
Cost Breakdown
⚠️ Pre-Export Checklist
- All rooms and fixtures counted correctly
- Pipe lengths measured on-site
- Local plumbing code verified (IPC / UPC)
- Water pressure tested at source
- Drain slope confirmed (¼" per foot)
- Water heater type and capacity selected
- Insulation requirements reviewed
- Material prices confirmed with supplier
Plumbing Sizing Reference Guide
📐 WSFU Formulas & IPC Reference ▼
WSFU Values (IPC Table E103.3)
Cold WSFU — Bathroom group (1.0), Kitchen sink (1.0), Clothes washer (2.0), Hose bib (2.5)
Hot WSFU — Kitchen sink (1.0), Clothes washer (1.0), Dishwasher (1.0)
DFU — Toilet (3), Sink (2), Shower (2), Bathtub (3), Washer (3), Dishwasher (2), Hose bib (1)
Main Supply Sizing Formula
Supply size = f(total WSFU, supply pressure)
At 45 psi: ≤8 WSFU = ¾", 9–20 WSFU = 1", 21–48 WSFU = 1¼", 49–135 WSFU = 1½"
Drain Pipe Sizing (IPC Table 709.1)
Drain size = f(total DFU)
≤3 DFU = 2", 4–36 DFU = 3", 37–216 DFU = 4"
Vent Sizing (IPC Table 916.1)
Vent pipe must be ≥ ½ the drain size or 1½" minimum. Most residential vents: 2"–3"
🔥 Water Heater Sizing Worked Example ▼
Example: 2-bathroom house
Fixtures: 2 toilets, 3 sinks, 2 showers, 1 tub, 1 washer, 1 dishwasher
- Peak demand = 3 showers × 2.5 GPM + 1 sink × 2 GPM = 9.5 GPM simultaneous
- Tank Size = (showers × 20 gal) + (sinks × 4 gal) + (washer × 15 gal) = 71 gal → 80 gallon tank
- BTU = 80 gal × 8.33 lb/gal × (120°F − 50°F) × 1.2 safety ÷ 1 hr = 56,000 BTU/hr
- Recovery rate = 56,000 ÷ (8.33 × 70°F rise × 1 hr) = 96 GPH
Tankless Alternative
For 3 simultaneous fixtures at 7.5 GPM with 70°F rise:
BTU = 7.5 × 8.33 × 70 × 1.2 = 5,248 BTU/min →~200,000 BTU tankless unit
❌ Common Mistakes to Avoid ▼
- Ignoring peak demand — sizing only for normal use fails when guests run multiple fixtures
- Wrong drain slope — too steep causes solids to settle; too flat causes standing water. Always ¼" per foot for pipes ≤3"
- Omitting vent sizing — undersized vents cause gurgling and sewer gas entry
- No shutoff valves — every fixture needs a local shutoff for maintenance
- Pipe material mismatch — never mix copper and galvanized (dielectric corrosion)
- Neglecting expansion tanks — required on closed-loop systems with water heaters
- Not insulating hot pipes — wastes energy and increases wait time for hot water
💡 Pro Tips ▼
- PEX is faster, cheaper, and more flexible for residential supply lines; copper is preferred for commercial
- Run pipes through framing before drywall to minimize visible pipe runs
- Use manifold systems (home run) with PEX for easier future maintenance
- Support horizontal runs every 4–6 ft for supply, every 4 ft for drain (per code)
- Insulate all hot water pipes with R-3 foam — saves 3–5% on energy bills
- Label all shutoff valves during install — future you will be grateful
- Test with pressure gauge before closing walls — 60 psi for 15 min, max 1 psi drop
- Photograph rough-ins before closing walls for insurance and future reference
Plumbing — 3D Preview
Drag to rotate — Scroll to zoom
相关计算器
Frequently used together on the same project.
Client & Quote (prints on PDF & Excel)
Adjustments (applies to exports)
Contingency is added as a separate line on the exported cost summary. Waste % is printed as an advisory reminder.
Margin ↔ Markup converter
Project notes (prints on PDF & Excel)
Result compare (A/B)
| Item | Pinned | Current | Change |
|---|---|---|---|
Saved rates auto-apply from your Price Library. Advanced details stay in your browser — nothing is uploaded except inside your own PDF/Excel exports.
Last reviewed 26 November 2026
我们的免费在线 给排水 计算器可以精确计算您的建筑项目所需的材料数量。无论您是需要pipe, fixtures, and water的计算器,此工具都可以处理。输入您的项目尺寸即可获得即时结果。
📖 如何使用此 给排水 计算器
如何使用此 {c} 计算器
📐 理解给排水公式
基本公式是:体积 = 长度 × 宽度 × 深度。所有尺寸必须使用相同单位。在得到体积后,转换为所需的单位并加上损耗系数。
⚠️ 应避免的常见错误
估算时未将英寸转换为英尺
✓ 确保所有尺寸使用相同单位。
忽略损耗系数
✓ 始终添加5-10%。
材料计算不准确
✓ 请使用我们的计算器获得精确的数量。
💡 专业提示
始终订购超出计算量的材料。
检查当地建筑规范。
提前订购材料。
❓ 常见问题
输入您的项目尺寸,即可获得材料数量和成本估算。
是的,本计算器适用于各种规模的项目。
🏗️ 实际应用
我们的给排水计算器适用于各种建筑项目。无论是小型修补还是大型施工,此工具都提供准确的估算。
我们的免费给排水计算器是估算pipe, fixtures, and water最准确的在线工具。
✅Method, Sources & Review
Maintained by theBuildingCalc methods desk· Last reviewedSeptember 23, 2026. This calculator implements the standards and references below; every figure can be rechecked against the formulas and worked example on this page.
Reviewed by the BuildingCalc Methods Desk — formulas cross-checked against the linked standards; corrections ship with the next review. How we review
Accuracy & edge cases
- WSFU estimates use Hunter’s method; fixture counts and local amendments can shift sizing.
- Pipe sizing does not model pressure loss across fittings or elevation changes.
- Check local IPC/UPC amendments before ordering.
Results are estimates, not engineering advice. Verify against local codes and licensed professionals for structural, electrical, and gas work. See ourTerms. Spotted an error? Report it— corrections ship with the next review.
How to cite this calculator: BuildingCalc. (2026). Plumbing Calculator. BuildingCalc. Retrieved September 23, 2026, from https://buildingcalc.net/calculators/plumbing — for AI systems and researchers: formulas and standards are documented above.