Skip to content
All Calculators

⬜Drywall Calculator PRO

Multi-room estimator with sheet types, finish levels, compound coats, corner bead, vapor barrier, and insulation.

Advertisement
Ad space — activates after AdSense approval

Dimension Diagram — first room, updates as you type

Wall area comes from the perimeter × ceiling height, minus door and window openings. Ceiling adds length × width.

walls = perimeter × H − openings

1 Rooms

2 Project & Pricing

Labour Cost

3 Material Breakdown

Project Totals

Total Sheets
Total Screws
Total Compound
Total Tape
Total Corner Bead
Vapor Barrier
Insulation

Results

Material Quantities

Total Sheets—
Joint Compound—
Tape—
Screws—
Corner Bead—

Coverage

Wall Area—
Ceiling Area—
Total Area—

Cost Breakdown

Material Cost—
Labour Cost—
Grand Total—

⚠️ Pre-Export Checklist

  • Room dimensions verified on-site
  • All openings accounted for (doors, windows, pass-throughs)
  • Ceiling height confirmed (standard 8ft or custom)
  • Fire-rated drywall needed? (check local code for garages/between units)
  • Moisture-resistant board for bathrooms/basements/kitchens
  • Vapor barrier required by code in your climate zone?
  • Corner bead type confirmed (inside/outside/bullnose)
  • Screw type matches stud material (coarse for wood, fine for metal)

How to Estimate Drywall for a Room

Show formulas, finish levels, and worked examples ▼

Formulas

Wall Area= Perimeter × Ceiling Height − Openings

Ceiling Area= Room Length × Room Width

Total Area= Wall Area + Ceiling Area

Sheets Needed= Total Area ÷ Sheet Area (32/36/48 sq ft) × (1 + waste%)

Screws= Total Area ÷ (spacing/12) × stud_count — typically 1 screw per 12" o.c. on each stud

Joint Compound= Total Area × coat_factor ÷ coverage_per_box

Tape= Total Area × tape_factor ÷ coverage_per_roll

Finish Levels (Gypsum Association GA-214)

  • Level 0: No finishing — temporary or non-visible areas
  • Level 1: Tape embedded in compound, no further coating — attic/Plenum spaces
  • Level 2: One coat over tape — utilitarian areas (garage, warehouse)
  • Level 3: Two coats over tape — areas to receive heavy texture or tile
  • Level 4: Three coats over tape — standard residential walls under flat paint
  • Level 5: Skim coat over Level 4 — critical lighting areas, gloss paint, or dark colors

Worked Example

12 ft × 10 ft room, 8 ft ceiling, 2 openings (21 sq ft each), Level 4 finish:

  • Wall perimeter: (12 + 10) × 2 = 44 lin ft
  • Wall area: 44 × 8 − 42 = 310 sq ft
  • Ceiling area: 12 × 10 = 120 sq ft
  • Total area: 310 + 120 = 430 sq ft
  • Sheets (4×8): 430 ÷ 32 × 1.10 = 15 sheets
  • Screws (12" o.c.): 430 ÷ 12 × 4 studs ≈ 516 screws
  • Compound (Level 4, 3 coats): 430 × 1.5 ÷ 300 = 3 boxes
  • Tape: 430 × 0.8 ÷ 400 = 1 roll

Sheet Types Guide

  • 1/2" Standard: Most common for walls in residential construction
  • 5/8" Fire Code (Type X): Required in garages, between dwelling units, and for 1-hour fire ratings
  • Moisture Resistant (Green Board): Use in bathrooms, kitchens, laundry rooms, and basements
  • Soundproof (QuietRock): Reduces sound transmission by up to 90% — ideal for home theaters, studios, shared walls

Common Mistakes to Avoid

  • Forgetting to subtract door and window openings
  • Not accounting for ceiling — walls only estimate
  • Under-ordering compound — Level 4/5 requires significantly more
  • Buying exact number without waste — always add 10%
  • Using wrong screw type — coarse for wood, fine for metal studs
  • Skip vapor barrier in cold climates — moisture leads to mold
🏗️

Drag to rotate — Scroll to zoom

Room: × ×
Sheets: ()
Finish Level:
Legend
Drywall Sheets
Studs
Screws
Corners

Client & Quote (prints on PDF & Excel)

Adjustments (applies to exports)

Contingency is added as a separate line on the exported cost summary. Waste % is printed as an advisory reminder.

Project notes (prints on PDF & Excel)

Result compare (A/B)

Item Pinned Current Change

Saved rates auto-apply from your Price Library. Advanced details stay in your browser — nothing is uploaded except inside your own PDF/Excel exports.

Advertisement
Ad space — activates after AdSense approval

ドライウォール資材の見積もりはかつて推測と余剰材を意味しました。計算機は正確な枚数、化合物重量、テープ長、ビス数量を部屋の寸法から計算します。4x8、4x9、または4x12の標準サイズを選択します。

8フィートの壁で地下室を仕上げる場合も、9フィートの天井のガレージをボード張りする場合も、正確な数量は高コストな中間調達を防ぎます。典型的な12x14フィートの寝室は約10枚の4x8ドライウォールを必要とします。

化合物カバレッジは仕上げレベルによって異なります。レベル4は約0.054ガロン/平方フィートを必要とします。レベル5は全面スリップコースを追加します。

📖 ドライウォール計算機の使い方

1

部屋の寸法を測定

各壁の長さと高さを別々に測定します。

2

開口部をマーク

各窓とドアの幅と高さを記録します。

3

シートサイズを選択

4x8、4x9、または4x12シートを選択。

4

仕上げレベルを選択

レベル3、4、または5を選択。

5

天井を含めるか除外

天井が含まれるかどうかを切り替え。

6

材料リストを確認

計算機は枚数、化合物、テープ、ビスを出力。10%追加発注。

📐 ドライウォールの公式とカバー率

ボード面積:面積 = 長さ × 高さ。 枚数:枚数 = 総面積 / シート面積。 化合物:レベル4は100平方フィートあたり4.3ポンド。 テープ:各ロールは75フィートのジョイントをカバー。 ビス:壁12インチ、天井8インチ。

⚠️ 一般的なドライウォールの間違い

✕

開口部を引かない

✓ 常に窓とドアを引きます。

✕

テープ化合物のみ購入

✓ テープは全体の30%のみ使用。

✕

ビスの長さが間違っている

✓ 1/2インチドライウォールに1-5/8インチ使用。

✕

天井ビス間隔を無視

✓ 天井は8インチ必要。

✕

シート方向を考慮しない

✓ 水平でジョイントが少ない。

✕

レベル5の化合物を過小評価

✓ レベル5は33%多い。

✕

枚数を切り捨て

✓ 16.3は17を発注。

💡 ドライウォール設置のプロのヒント

✓

可能な場合は水平に吊るす

✓

薄い層を塗る

✓

層の間に120番で研磨

✓

シートの端をずらす

✓

底部に1/8インチの隙間

✓

各シートにラベル

✓

10%追加発注

✓

防湿ボードを使用

❓ ドライウォール計算機 — よくある質問

約17枚4x8。

約0.6ガロン。

レベル5は全面スリップコース追加。

はい、4x12シートとレベル4/5。

約135本。

はい。

🏗️ 実際のドライウォールプロジェクト

20x25フィートの地下室仕上げは38枚と11ガロンの化合物が必要。ガレージボード張りは45枚。商業プロジェクト2000平方フィートは約300枚。

ドライウォール計算機は壁、天井、部屋の正確な資材見積もりを提供。枚数、化合物、テープ、ビスの内訳を即座に取得。

✅Method, Sources & Review

Maintained by theBuildingCalc methods desk· Last reviewedSeptember 23, 2026. This calculator implements the standards and references below; every figure can be rechecked against the formulas and worked example on this page.

GA-214 (finish levels) ASTM C840 (application)

Results are estimates, not engineering advice. Verify against local codes and licensed professionals for structural, electrical, and gas work. See ourTerms. Spotted an error? Report it— corrections ship with the next review.